Flow rate is an instantaneous value, measured after 60 seconds of stabilization.
The flow is regulated on the pressure range from 1 to 10 bar.
If no flow regulator is used, the appliance must warranty that the flow rate will never be higher than 20 litre/minute
New solenoid design, expanding applications for the valve.
Global standardization of the manufacturing process and equipment as well as the product design, ensuring there is not variation of quality or performance allowing you to source the Hydra valve wherever and whenever you need it.

Rated voltage:

220-240V 50-60Hz, 110-120V 50-60Hz

12VAC & VDC; 24VAC & VDC (EU)

Power :

5 - 6 watt at 230V

Coil insulation:

Class F (Max 140°C wire operating temperature)

Ambient temperature:

85°C maximum according water temperature & duty cycle

Water temperature:

90°C maximum according water temperature & duty cycle

Operating duty cycle:

Tu 25°C, Tm 90°C & Tu 60°C, Tm 25°C, continuous (100%ED)

(220-240V)

Tu 25°C, Tm 90°C, 3 minutes ON, 5 minutes OFF

Operating pressure range:

0.2 to 10 bar

Flow regulator (optional):

0.25 to 17 litre/minute

Fluid

Water

Insulation:

Class II to water. No grounding required

Coil terminals:

Two 6.35x0.8mm male tabs terminals, RAST2.5

Agency approvals:

Upon request: CQC, ENEC, UL (WRAS for Hydra)

Internal leakage

Maximum 1 drop/minute on pressure range 0.2 to 10 bar

External leakage

10 bar  / 10 min

Burst Pressure

80 bar

 

FLOW Litre/min

Tolerance

 

FLOW Litre/min

Tolerance

2,5

15%

 

0.25

+/-0.1

3

15%

 

0.35

+/-0.1

3.5

15%

 

0.50

+/-0.15

3.75

15%

 

0.65

+/-0.25

4

15%

 

0.80

+/-25%

5

15%

 

1.2

+/-25%

5.5

15%

 

1.3

+/-25%

6

15%

 

2

+/-25%

7

15%

 

2.5

+/-20%

8

15%

 

3.3

+/-20%

9

15%

 

3.8

+/-20%

10

15%

 

5

+/-15%

11

15%

 

 

 

12

15%

 

 

 

14.5

15%

 

 

 

15

15%

 

 

 

17

25%

 

 

 

Flow rate is an instantaneous value, measured after 60 seconds of stabilization.
The flow is regulated on the pressure range from 1 to 10 bar.
If no flow regulator is used, the appliance must warranty that the flow rate will never be higher than 20 litre/minute
New solenoid design, expanding applications for the valve.
Global standardization of the manufacturing process and equipment as well as the product design, ensuring there is not variation of quality or performance allowing you to source the Hydra valve wherever and whenever you need it.

Rated voltage:

220-240V 50-60Hz, 110-120V 50-60Hz

12VAC & VDC; 24VAC & VDC (EU)

Power :

5 - 6 watt at 230V

Coil insulation:

Class F (Max 140°C wire operating temperature)

Ambient temperature:

85°C maximum according water temperature & duty cycle

Water temperature:

90°C maximum according water temperature & duty cycle

Operating duty cycle:

Tu 25°C, Tm 90°C & Tu 60°C, Tm 25°C, continuous (100%ED)

(220-240V)

Tu 25°C, Tm 90°C, 3 minutes ON, 5 minutes OFF

Operating pressure range:

0.2 to 10 bar

Flow regulator (optional):

0.25 to 17 litre/minute

Fluid

Water

Insulation:

Class II to water. No grounding required

Coil terminals:

Two 6.35x0.8mm male tabs terminals, RAST2.5

Agency approvals:

Upon request: CQC, ENEC, UL (WRAS for Hydra)

Internal leakage

Maximum 1 drop/minute on pressure range 0.2 to 10 bar

External leakage

10 bar  / 10 min

Burst Pressure

80 bar

 

FLOW Litre/min

Tolerance

 

FLOW Litre/min

Tolerance

2,5

15%

 

0.25

+/-0.1

3

15%

 

0.35

+/-0.1

3.5

15%

 

0.50

+/-0.15

3.75

15%

 

0.65

+/-0.25

4

15%

 

0.80

+/-25%

5

15%

 

1.2

+/-25%

5.5

15%

 

1.3

+/-25%

6

15%

 

2

+/-25%

7

15%

 

2.5

+/-20%

8

15%

 

3.3

+/-20%

9

15%

 

3.8

+/-20%

10

15%

 

5

+/-15%

11

15%

 

 

 

12

15%

 

 

 

14.5

15%

 

 

 

15

15%

 

 

 

17

25%

 

 

 